Normal range of left ventricular strain, dimensions and ejection fraction using three-dimensional speckle-tracking echocardiography in neonates


King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia

Correspondence Address:
Ziad Bulbul
King Faisal Specialist Hospital and Research Centre, Heart Center MBC-16, P. O. Box: 3354, Riyadh 11211
Saudi Arabia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2211-4122.166074

Rights and Permissions

Aims: Three-dimensional speckle-tracking echocardiography (3D-STE) is a promising new technique to evaluate left ventricular (LV) mechanics. The feasibility and normal values of LV strain using 3D-STE have recently been established in adults and children. Unfortunately, no data are available in neonates. The aims of this study were to evaluate the feasibility and establish normal values of 3D LV volumes, ejection fraction (EF), and the 4 normal strains in healthy neonates. Materials and Methods: Of 50 consecutive newborns who were delivered at our hospital or returned to their first newborn follow-up within the first 3 weeks of life, 38 babies underwent full echocardiographic evaluation, including the acquisition of at least 3 full volume data sets from the apical window, while naturally sleeping. Data sets were analyzed offline. Global LV longitudinal, circumferential, and radial strain, as well as 3D LV volumes and EF, were measured using 3D-STE. Results: Of the 50 newborns, 2 patients were excluded because of significant intra-cardiac shunts, and in another 10 subjects, parents did not give consent. At least one data set was adequate for analysis in all the remaining subjects. Mean indexed LV diastolic, systolic volumes, and EF were 24.7 ± 3.6 ml/m 2 , 9.2 ± 1.3 ml/m 2 , and 63% ± 3.7%, respectively. Normal global longitudinal, circumferential, radial, and tangential 4D strain were −20.9% ± 2.8%, −32.4% ± 3.1%, 44.3% ± 3.4%, and −39.7% ± 3.4%, respectively. Conclusions: 3D-STE is feasible in newborns without the needed for sedation. Reference values of normal, regional, and global LV 4D strain and volumes were obtained.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3311    
    Printed38    
    Emailed0    
    PDF Downloaded181    
    Comments [Add]    

Recommend this journal